Back to Top

Hi, Guest!

  LOKASI :  Kabupaten Bekasi

Bergabung Selama :

BAGIKAN :   

Bagikan :
  • ECG( Elektrocardiography) type MAC-400 GE

ECG( Elektrocardiography) type MAC-400 GE

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
0
Dilihat Sebanyak
:
59 kali

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail ECG( Elektrocardiography) Type MAC-400 GE

EKG/ ECG / Electrocardiography Type MAC-400 GE Healthcare Instrument Type Microprocessor augmented automatic electrocardiograph; 10-leadwire acquisition with programmable lead configuration Processing Acquisition & Analysis 12 leads – simultaneous Signal input Type CF according to IEC. However, not intended for direct cardiac application. Digital Sampling > 1000 samples/ second/ channel ECG analysis frequency 500 samples/ second/ channel Dynamic Range AC Differential ± 5mV, DC offset ( Polarization voltage) ± 300 mV Resolution 5 ¼ V Frequency Response 0.01 to 150 Hz Low cut-off frequency 0.01 Hz, 0.04 Hz, 0.08 Hz or 0.16 Hz ( -3 dB limits) , equivalent to a time constant of 16 s, 4 s, 2s or 1 s High cut-off frequency 150 Hz ( -3 dB limits) , 35 Hz or 20 Hz if muscle filter is enabled Common Mode Rejection > 100 dB @ 50/ 60 Hz ( AC filter switched on) Input Impedance > 10 M© @ 10 Hz Defibrillator protected Patient leakage < 10 ¼ A Operating modes Automatic ( 12lead data) , Manual ( real-time data) , Arrhythmia ( continuous monitoring) Lead Printout Sequence Standard ( Einthoven) , Cabrera Report formats Automatic: simultaneous ( short and long format) , sequential ( with and without rhythm) Manual: 1 or 3 channel real time printout Arrhythmia: continuous monitoring with event documentation Heart rate meter 30 to 300 BPM ± 2% or ± 1 BPM, whichever is greater. Heart rates outside this range will not be displayed. Baseline Adjustment Automatic adjustment of the baseline to the optimal recording range. Anti-Drift System ( ADS) Automatic compensation of baseline Lead-fail indication Audible and visual indication of disconnected electrodes or line break; each single electrode is monitored except N/ right leg Software Options Marquette 12SL ECG based measurement package gives QRS, QT/ QTC, PR, P, RR/ PP, and P/ QRS/ T Marquette 12SL ECG based analysis package for Analysis and Interpretation Display Type LCD, 2 row x 16 character alphanumeric, with adjustable contrast. Displayed Data Selected Lead Group, Operation Mode, Lead Check, Heart Rate, AC Filter, Muscle Filter, Gain, Speed Examples of ECG reports with Marquette 12SL analysis and interpretation program. The interpretation program is optional.GE imagination at work General Electric Company reserves the right to make changes in specifications and features shown herein, or discontinue the product described at any time without notice or obligation. GE, GE Monogram, MAC® , Marquette® 12SL™ are trademarks of General Electric Company. GE Medical Systems Information Technologies GmbH, a General Electric company, doing business as GE Healthcare. 2036097-002-2007.10-V2.0 Writer Writer technology Thermal array print head Resolution Vertical 8 dots/ mm, horizontal 40 dots/ mm at 25 mm/ s Number of traces 3 in automatic and arrhythmia modes, 1 or 3 in manual mode Annotation of device settings, date and time in the margin of recording strip Writer speeds 5, 25, 50 mm/ s Writer sensitivity/ gain 5, 10, 20 mm/ mV Paper type Z-fold, Roll, Paper size Width 80mm, Z-fold Sheet length 90 mm, 280 sheets/ pack Roll paper length 15.7 m Writer speeds accuracy Typical ± 1% , maximum ± 5% Writer amplitude accuracy ± 5% Keyboard Type Membrane keypad with tactile feedback Power Supply Ratings 100 to 240 V ± 10% Frequency 50/ 60 Hz ± 10% Battery Type Lithium ion, 7.2 V Battery Charge Time Approximately 3 hours Battery charging Automatic battery charging via built-in charger during line-power operation Battery capacity 100 Automatic ECG recordings or operating time of 4 hrs without recording Your local contact: Physical specifications Width 263 mm Height 78 mm Depth 208 mm Weight 1.3 kg/ 2.86 lb with battery Environmental specifications Temperature ( with battery) Transport/ Storage -15° C to + 50° C Operating + 10° to 40° C Relative humidity Transport/ Storage 25-95% Operating 25-95% Pressure Transport/ Storage 500 to 1060 hPa Operating 700 to 1060 hPa Certification a) UL 60601-1 classified b) UL classified for CAN/ CSA C22.2 No. 601.1 c) CB certified for IEC 60601-1, IEC 60601-2-25 d) CE marking for Council Directive 93/ 42/ EEC concerning medical devices e) Meets applicable AAMI EC-11 requirements Warranty Standard Warranty is 1 year. Ordering Informasi nuhamedical.com Visit gehealthcare.com or contact your local GE Healthcare representative
Tampilkan Lebih Banyak